How to maintain the welding positioner

Oct 26, 2021 Leave a message

One: Daily maintenance regulations

(1) After each welding of the workpiece, the welding slag on the workbench should be cleaned up in time.

(2) Before using the equipment, check the rotating gears, flip gears, and cables. If there is dirt on the rotating gears and flip gears, remove them in time. If the cables are broken or broken In case of problems such as poor contact, repair them in time, and replace them if they cannot be repaired. In addition, the rotating gears and flip gears should be lubricated, and appropriate lubricating oil should not be excessive.

(3) When the work is over, all records should be filled in for later investigation.

Two: Level 1 maintenance regulations

(1) Check the distribution box. If there is dust, remove it in time and check whether the wiring terminals are firm. If there is any looseness, they should be fastened in time.

(2) Whether the rotation of the rotary shaft and bearing of the worktable is smooth, whether there is abnormal noise, and if the bearing is worn, it should be replaced in time.

(3) Check the lubricating oil to see if the amount of oil is sufficient and the oil quality is good.