Lubrication maintenance:
1. Check the oil level: The device must be stopped and upright, and the oil level must be checked using a sight glass. The lubricating liquid level should reach the top of the sight glass.
2. Refueling operation: When refueling, remove the pipe plug or screw at the corresponding position, refuel to the appropriate level, replace the filler bolt and tighten it.
3. Oil change operation: For different models of welding rotary tables, the oil change steps are different, but generally include stopping and uprighting the device, emptying the old oil, cleaning the rotary table, and filling with new oil.
Coolant maintenance:
1. The machine tool coolant must be a water-soluble, synthetic oil-based coolant/lubricant.
2. Never use mineral cutting oil, pure water or flammable liquids as coolant.
3. Avoid immersing the device in the coolant, and keep the coolant pipes on the workpiece away from the rotary device when spraying.
4. Check whether the cables and gaskets are cut or swollen, and repair damaged components immediately.
Other inspections:
1. The specifications of end face runout, end face inner diameter runout, worm clearance, backlash between worm and gear, and ejection value have been set in the factory and cannot be repaired on site. If it exceeds the range, please contact a professional.